Table 1-2. HP 3048A System Option Specifications (4 of 9)
OPTIONS 003 OR 004: ADDING THE HP 11729C
OR 11729C OPT 130 CARRIER NOISE TEST SET
The following data is applicable to using the HP 11729C to
downconvert the test signal to an IF of between 5 MHz and
1280 MHz for subsequent demodulation using the Low
Frequency phase detector of the HP 3048A system, The
HP 8662A Opt. 003 or 8663A Opt. 003 Signal Generators
provide a 640 MHz reference signal for this downcoversion
process. These signal generators also provide a signal of
between 5 MHz to 1280 MHz to demodulate the
downconverted IF noise. The specifications that follow assume
this measurement set-up is used.
Input Requirements
Frequency
Measurement Frequency Range: 5 MHz to 18 GHz in 8
bands,
excluding ±5 MHz around band center frequencies.
Band Center Frequencies: 1.92 GHz, 4.48 GHz, 7.04 GHz,
9.60 GHz, 12.16 GHz, 14.72 GHz, 17.28 GHz.
Amplitude
For carrier frequencies <1.28 GHz: -5 dBm minimum to
+23 dBm maximum.
For carrier frequencies >1.28 GHz: +7 dBm minimum to
+20 dBm maximum.
Measurement Specifications
Offset Frequency Range
For carriers between 5 and 95 MHz from band centers:
0.01 Hz to 2 MHz.
For carriers >95 MHz from band center: 0.01 Hz to
40 MHz.
(Assumes addition of 40 MHz spectrum analyzer to the
system, otherwise offset frequency range limited to
100 kHz.)
System Noise Floor
3
Absolute System Noise Floor (dBc/Hz), when used with the
HP 11729C and HP 8662A Option 003 or HP 8663A Option
003 as the reference source, phase locking via the signal
generator's EFC.
3
Specified only with FM off.