Agilent B2900 SCPI Command Reference, Edition 2 4- 87
Subsystem Commands
:SENSe:RESistance:OCOMpensated
Parameter mode MANual (default)|AUTO. Parameter data type is CPD.
If mode=MANual is selected, the source and measurement condition must be set
manually. If the resistance measurement function is enabled, the resistance is
calculated by voltage/current. The resistance measurement range cannot be set.
If mode=AUTO is selected, the channel automatically sets the current source and
voltage measurement if the resistance measurement function is enabled. The current
output value and range depend on the resistance measurement range selected by the
:SENS:RES:RANG:UPP or SENS:RES:RANG:AUTO:LLIM and
:SENS:RES:RANG:AUTO:ULIM commands. And the following parameters are set
automatically.
Source output mode: CURRent
Source current automatic ranging: OFF
Source output shape: DC
Source current mode: FIXed
Voltage measurement range: 2 V range
Voltage compliance: 2.1 V
Voltage measurement automatic range: OFF
High capacitance mode: OFF
Query response mode <newline>
mode returns MAN or AUTO, and indicates the resistance measurement mode.
Response data type is CRD.
Example :SENS:RES:MODE MAN
:SENS2:RES:MODE?
:SENSe:RESistance:OCOMpensated
Enables or disables the offset-compensated resistance measurement.
Syntax :SENSe[c]:RESistance:OCOMpensated mode
:SENSe[c]:RESistance:OCOMpensated?
Parameter mode 1|ON|0|OFF (default). Parameter data type is boolean.
mode=0 or OFF disables offset-compensated resistance measurement.